DESCRIPTION 

F1 Ultra low humidity dry cabinet is a plug and play, fully auto-dry cabinet which stables the cabinet condition at 1%RH. There is no need to set the panel buttons at all. It is specially designed for moisture sensitive SMD packages to comply with J-STD-033B.

MODEL F1-1200-6  ULTRA LOW HUMIDITY DRY CABINET (1%RH) 


  Ultra Dry Cabinet Model F1-series

bullet

Precision/Accuracy: 3.0%RH, 1C

bullet

Humidity Range: 1%RH.

bullet

Recovery time: Open door 30 seconds and close, 15 mins recovery time to <5%RH, 30 mins recovery time to <2%RH

bullet

Outside Dimension: W1200xD672xH1820 mm

bullet

Capacity: 1250L

bullet

Shelves: 5 shelves

bullet

Color: black

bullet

Voltage: 230V

bullet

Display Precision: 1C, 3%RH

bullet

Software: Humidity Manager V2 for drawing the curve of RH and temperature.

bullet

Structure: 1mm thick carbon steel with antistatic paint.

bullet

Door: Handles, airtight magnetic sealers and antistatic glass.

bullet

Wheel: four antistatic 3 wheels, two of them with brakes.

bullet

Grounding Wire: 1MΩ. (940mm long)

bullet

ESD Paint: 103~109Ω. (surface resistance)

bullet

Power Consumption: Ave. 135Wh; Max. 425W

GENERAL 
bullet Internal dimensions (mm: W1198xD645xH1618
bullet Shelf dimensions (mm): W1155xD530xH20
bullet Power consumption: Ave. 135Wh; Max. 425W
CONTROL PANEL   EXTENDED BIN  

Extended Bin (option) for the Model F1-series

INFORMATION  
 
COMPARISON SHEETS  
to Model F1 Product Specification Chart
to Product Specification Chart
STANDARD FEATURES  
bullet

Flash and Buzz alarm; Built-in humidity and temperature alarm; upper and lowers limits can be set.

bullet

Built-in calibration reminding; world's first and only dry cabinet that complies with ISO standard. cleaning

bullet

PPS Heat resistant material;  Used on all dryers; 260C heat tolerance to avoid any deforming or melting of dryer.  

bullet

Built-in RS232 port to be used with our software for instant monitoring and graphing of condition inside the cabinet.

bullet

Computerized humidity management that replaced human recording; be aware of the condition inside the cabinet at all time.