The HT-Series furnace operates in mid-range infrared by
combining both infrared and ultra-violet heating elements.The combination of these two enables the furnace to reach
temperatures of up to 1300 °C.. The HT-Series furnace is capable of
handling both high temperature processing tasks and mid-range temperature
tasks.
OPTIONS
RTC HT-Series Furnaces
(click on picture to enlarge)
Oxygen Analyzer
Moisture Analyzer
Hydrogen Operation, Hydrogen/Nitrogen Mixing
Hydrogen Detector
On-Screen Profiling
Ultrasonic Cleaner with Optional Dryer
Belt Brush Cleaner
Air Purification System
Air Filter Regulator
Emergency Power Supply
Uninterruptible Power Supply
Element Monitor
Conveyor Extensions
Redundant Over Temperature Scanner/Shutdown
Electrical Line Filter
Low
Range Belt Speed (0.5 to 10 in./min.)
RTC Software Program, PC/HOST Communications and
Protocol
200-240 volts, 3 phase, 50-60 Hz or 380-480 volts, 3
phase, 50-60 Hz.
Tungsten filament in Halogen back filled quartz.
Over temperature protection.
NORMAL
OPERATING TEMPERATURE
COMPUTERIZED CONTROL SYSTEM
125-1000°C.. Cross-belt
temperature uniformity: +/- 1.5°C.. Class 100 cleanliness
PLC with PC and user-friendly MMI control system and
instrumentation, includes PID control, data acquisition, diagnostic
capabilities and real-time remote operation.